Modules / Tools / Cluster network sizer

Cluster network sizer

Size an AI cluster network: accelerators, links, switch radix, fat-tree tiers, oversubscription, optics count, power and collective communication time.

AI, systems and startupFree to useHow it worksSourcesWhere it helps

Fills the inputs below with typical figures. Replace any of them with your own.

Cluster

Each port is a link into the fabric.

Switch

One switch type is used in every tier.

Excluding the optics, which are counted below. 750 W is the typical figure for a 64-port 400 Gb/s switch with passive cables.

Topology

A rail is the same port number in every server. Each rail gets its own leaf switches.

1 is non-blocking: as many uplinks as downlinks.

Cables and optics

Choose the cable on each tier. Leave the powers at 0 for the typical figure for the link speed.

All-reduce

The alpha-beta model: each step costs a latency plus the bytes sent over the bandwidth.

The data each accelerator reduces, for example the gradients of one step.

For the hierarchical algorithm. Editorial default; use your server's figure.

Share of line rate a collective reaches.

Choose yes for a pessimistic bound when ranks are spread across leaves.

Switches
48
32 leaf, 16 spine (2 tiers, 64 ports each)
Links and cables
2,048
1,024 accelerator to leaf, 1,024 leaf to spine
Pluggable transceivers
2,048
2,048 active optical cable ends, 0 copper cables
Network power
69.18 kW
67.56 W for each accelerator; switches 36 kW, optics 33.18 kW
Bisection bandwidth
204,800 Gb/s
400 Gb/s sustained for each accelerator across the fabric (400 Gb/s at the port)
Fastest all-reduce
10.7 ms
Hierarchical ring, 1 GB over 1,024 accelerators
Port use
100.0%
Leaf split: 32 down and 32 up (1 to 1)

Check these

  • Rail-optimised: the leaf switches of one rail serve only that rail's port in every server. Same-rail traffic crosses one leaf; traffic between rails crosses the spine tier or the links inside the server.
Switches by tier
  • Leaf32
  • Spine16
Show the data as a table
Switches by tier
ItemSwitches
Leaf32
Spine16
Where the network power goes
  • Switches36 kW
  • Pluggable transceivers18.43 kW
  • Active optical cable ends14.75 kW
Show the data as a table
Where the network power goes
ItemPower
Switches36 kW
Pluggable transceivers18.43 kW
Active optical cable ends14.75 kW

Sign in to save your inputs and come back to them later.

Links and optics by tier
TierLinksCablePluggable transceiversAOC ends
Accelerator to leaf1,024Active optical cable (AOC)02,048
Leaf to spine1,024Pluggable transceivers and fibre2,0480
All-reduce time against message size
Line chart of All-reduce time (log scale) against Message size per accelerator (log scale), 4 lines: Ring over all accelerators, Hierarchical ring, Halving and doubling (Rabenseifner), Recursive doubling. The same numbers are in the table under the chart.100 µs1 ms10 ms100 ms1 s10 KB1 MB100 MB10 GBMessage size per accelerator (log scale)All-reduce time (log scale)
  • Ring over all accelerators (solid line, circles)
  • Hierarchical ring (dashed line, squares)
  • Halving and doubling (Rabenseifner) (dotted line, triangles)
  • Recursive doubling (dash-dot line, diamonds)
Show the data as a table
All-reduce time against message size
Message size per accelerator (log scale)Ring over all acceleratorsHierarchical ringHalving and doubling (Rabenseifner)Recursive doubling
1 KB10 ms1.27 ms98 µs49.2 µs
3.16 KB10 ms1.27 ms98.1 µs49.7 µs
10 KB10 ms1.27 ms98.4 µs51.2 µs
31.6 KB10 ms1.27 ms99.4 µs56 µs
100 KB10 ms1.27 ms102 µs71.2 µs
316 KB10 ms1.28 ms112 µs119 µs
1 MB10.1 ms1.28 ms142 µs271 µs
3.16 MB10.2 ms1.3 ms238 µs752 µs
10 MB10.5 ms1.37 ms542 µs2.27 ms
31.6 MB11.4 ms1.57 ms1.5 ms7.08 ms
100 MB14.5 ms2.21 ms4.54 ms22.3 ms
316 MB24.1 ms4.25 ms14.1 ms70.3 ms
1 GB54.4 ms10.7 ms44.5 ms222 ms
3.16 GB150 ms31 ms141 ms703 ms
10 GB454 ms95.3 ms444 ms2.22 s

Both axes are logarithmic. Ring methods pay a latency for every one of the 2 (p − 1) steps, so they lose to halving and doubling for small messages and to the hierarchical ring when servers hold several accelerators.

All-reduce of 1 GB over 1,024 accelerators
AlgorithmTimeAlgorithm bandwidthBus bandwidth
Ring over all accelerators54.4 ms147 Gb/s293.7 Gb/s
Hierarchical ring (fastest)10.7 ms749.5 Gb/s1,498 Gb/s
Halving and doubling (Rabenseifner)44.5 ms179.8 Gb/s359.2 Gb/s
Recursive doubling222 ms35.99 Gb/s71.91 Gb/s
Fastest all-reduce method by message size
Message sizeRing over all acceleratorsHierarchical ringHalving and doubling (Rabenseifner)Recursive doublingFastest
1 KB10 ms1.27 ms98 µs49.2 µsRecursive doubling
64 KB10 ms1.27 ms101 µs63.2 µsRecursive doubling
1 MB10.1 ms1.28 ms142 µs271 µsHalving and doubling (Rabenseifner)
16 MB10.7 ms1.42 ms808 µs3.6 msHalving and doubling (Rabenseifner)
256 MB21.4 ms3.68 ms11.5 ms56.9 msHierarchical ring
1 GB54.4 ms10.7 ms44.5 ms222 msHierarchical ring
4 GB188 ms38.9 ms178 ms889 msHierarchical ring
What if the link speed changed: all-reduce of 1 GB
Link speedRing over all acceleratorsHierarchical ringHalving and doubling (Rabenseifner)Recursive doubling
100 Gb/s188 ms27.2 ms178 ms889 ms
200 Gb/s98.8 ms16.2 ms88.9 ms444 ms
400 Gb/s54.4 ms10.7 ms44.5 ms222 ms
800 Gb/s32.2 ms7.92 ms22.3 ms111 ms
1,600 Gb/s21.1 ms6.54 ms11.2 ms55.6 ms

How it works

An AI training cluster needs a network that can move gradients and activations between thousands of accelerators without becoming the bottleneck. This tool sizes a fat-tree (Clos) fabric from the number of accelerators, the ports and speed of each, and the switch radix: how many leaf, spine and core switches, how many links and optical transceivers, what the network draws, how much bandwidth crosses its middle, and how long an all-reduce takes.

  1. Count the endpoints and the usable radix. Every accelerator port that joins the network is an endpoint. A switch port that is faster than the link can be split (breakout), for example one 800 Gb/s port into four 200 Gb/s links; a slower one must be joined in groups. The result is the radix: how many links one switch can take at the link speed.endpoints = accelerators x ports per accelerator; radix = switch ports x floor(switch speed / link speed)
  2. Split each leaf between servers and uplinks. A leaf switch gives some of its ports to accelerators (down) and the rest to the next tier (up). With no oversubscription the two are equal. An oversubscription ratio of r to 1 means r times more downlink than uplink capacity. In a rail-optimised design the leaf switches of one rail serve only that rail's port in every server, so each rail is counted as a group.up = floor(radix / (1 + r)); down = radix − up; leaf switches = ceiling(endpoints in the group / down), summed over the groups
  3. Count the spine tier. The uplinks of all leaf switches land on spine switches. In a two-tier fabric the spine uses every port for leaf links, and every spine must reach every leaf, so there can be no more leaf switches than the radix. This is the leaf-spine arrangement of a fat tree, as Al-Fares, Loukissas and Vahdat describe for commodity switches.leaf-spine links = ceiling(endpoints x up / down); two-tier spine switches = ceiling(leaf-spine links / radix)
  4. Add a core tier for three tiers. In a three-tier fabric the spine also splits its ports between leaf links (down) and core links (up) at its own oversubscription ratio, and the core joins the pods. A non-blocking fabric of switches with k ports reaches k^3 / 4 endpoints.spine switches = ceiling(leaf-spine links / spine down); spine-core links = ceiling(leaf-spine links x spine up / spine down); core switches = ceiling(spine-core links / radix)
  5. Count cables, transceivers and power. Each link is one cable. A link on pluggable optics needs two transceivers, one at each end; an active optical cable has its optics built into both ends; passive copper has none. Network power is the switches plus the optics, with a typical figure per module chosen from the line speed unless you enter your own.transceivers = 2 x optical links; power = switches x switch power + transceivers x module power + AOC ends x end power
  6. Find the bandwidth across the fabric. Each endpoint injects at the link speed. The bandwidth across the middle of a full fat tree is half the endpoint total; oversubscription at each tier divides it, and the same ratio limits what one accelerator can sustain when its traffic crosses the fabric.bisection bandwidth = endpoints x link speed / 2 / (leaf ratio x spine ratio); sustained per accelerator = ports x link speed / (leaf ratio x spine ratio)
  7. Time the all-reduce with the alpha-beta model. A message of m bytes takes alpha seconds to start and m / beta seconds to send, where beta is the bandwidth of one accelerator across the network times a transport efficiency. A ring all-reduce over p accelerators runs a reduce-scatter and an all-gather of p − 1 steps each. Halving and doubling (Rabenseifner) takes about lg p steps, and recursive doubling suits small messages. The hierarchical ring reduces inside each server first, runs the ring across servers on each accelerator's share, then gathers inside the server. Alpha is the interface latency plus the switch traversals of the longest path.ring: T = 2 (p − 1) alpha + 2 (p − 1) / p x m / beta; halving and doubling: T = 2 lg(p) alpha + 2 (p − 1) / p x m / beta; recursive doubling: T = lg(p) alpha + lg(p) x m / beta

Assumptions

  • The fabric is a folded Clos (fat tree) built from identical switches, fully populated up to the last leaf, with every link at the same speed.
  • Rail-optimised means the leaf switches of one rail serve only that rail's port in every server; the spine and core tiers are shared between rails.
  • Spine and core counts are rounded up from the link totals; real designs may add switches to keep the pods symmetrical.
  • The all-reduce uses the whole of an accelerator's network bandwidth, at an efficiency you set (90% by default), and every step of a ring has the latency of the longest path. Real libraries pick algorithms and overlap steps.
  • Power per module and per switch, latencies and the in-server bandwidth are editorial defaults. The switch default (750 W) is the typical figure NVIDIA gives for a 64-port 400 Gb/s InfiniBand switch with passive cables; optics are counted apart.

Limits and warnings

  • Links inside the server (NVLink and similar) and the scale-up network are not sized here; they appear only as the in-server bandwidth of the hierarchical all-reduce.
  • Congestion, adaptive routing and imperfect load balancing lower the bandwidth below the ideal that a non-blocking fat tree gives.
  • Twin-port switch cages (two links in one module) halve the module count at the switch; the transceiver count here assumes one module per link end.
  • The model does not size storage, management or out-of-band networks, or the cost of the parts.
  • The latency term for a large ring is the main reason hierarchical or tree methods win; the numbers depend on the latency figures entered, so measure your fabric.
  • The reduction arithmetic itself (the gamma term in the full cost model) is left out; it is small next to the network time for gradients on current accelerators.

Sources

The methods and default figures rest on these public sources. The wording here is our own; read the source for its full text.

Where it helps

The lifecycle stages this tool serves: 1 stage in 1 lifecycle.

Method notev1Formula, ranges, sources and limits

Sizes the leaf, spine and core switches, links, optics, power and bisection bandwidth of an AI cluster fat tree, and the ring all-reduce time from an alpha-beta model.

Formula

endpoints = accelerators x ports per accelerator; radix = switch ports x floor(switch speed / link speed); up = floor(radix / (1 + r)); down = radix − up; leaf switches = ceiling(endpoints in the group / down), summed over the groups; leaf-spine links = ceiling(endpoints x up / down); two-tier spine switches = ceiling(leaf-spine links / radix); spine switches = ceiling(leaf-spine links / spine down); spine-core links = ceiling(leaf-spine links x spine up / spine down); core switches = ceiling(spine-core links / radix); transceivers = 2 x optical links; power = switches x switch power + transceivers x module power + AOC ends x end power; bisection bandwidth = endpoints x link speed / 2 / (leaf ratio x spine ratio); sustained per accelerator = ports x link speed / (leaf ratio x spine ratio); ring: T = 2 (p − 1) alpha + 2 (p − 1) / p x m / beta; halving and doubling: T = 2 lg(p) alpha + 2 (p − 1) / p x m / beta; recursive doubling: T = lg(p) alpha + lg(p) x m / beta

Inputs
InputUnitRange it holds forComes from
Acceleratorscount1 to 1000000Your figure
Accelerators per servercount1 to 64Your figure
Network ports per acceleratorcount1 to 8Your figure
Link speedchoice100, 200, 400, 800, 1600Your figure
Switch portscount2 to 512Your figure
Switch port speedchoice100, 200, 400, 800, 1600Your figure
Topologychoicetwo-tier, three-tierYour figure
Rail-optimisedchoiceyes, noYour figure
Leaf oversubscriptionto 11 to 8Your figure
Spine oversubscriptionto 11 to 8Your figure
Accelerator to leaf cablechoicedac, aoc, opticalYour figure
Leaf to spine cablechoicedac, aoc, opticalYour figure
Spine to core cablechoicedac, aoc, opticalYour figure
Power per transceiver, 0 for the typical figureW0 to 60Your figure
Power per AOC end, 0 for the typical figureW0 to 60Your figure
Power per copper cable endW0 to 5Your figure
Power per switchW0 to 20000Your figure
All-reduce message sizeentered unitfrom 0Your figure
Unit of the message sizechoicekb, mb, gb, mib, gibYour figure
Interface and software latency per stepµs0 to 1000Your figure
Latency per switch traversalns0 to 100000Your figure
Bandwidth between accelerators in a serverGB/s each way0 to 10000Your figure
Latency inside a server per stepµs0 to 1000Your figure
Transport efficiency%1 to 100Your figure
Divide collective bandwidth by the oversubscriptionchoiceyes, noYour figure
Unit for bandwidth resultschoicegbps, gbs, tbps, tbsYour figure

Outputs: Leaf switches (switches); Spine switches (switches); Core switches (switches); Pluggable transceivers (modules); Cables (cables); Network power (kW); Bisection bandwidth (Tb/s); Ring all-reduce time (ms); Hierarchical all-reduce time (ms).

Assumptions

  • The fabric is a folded Clos (fat tree) built from identical switches, fully populated up to the last leaf, with every link at the same speed.
  • Rail-optimised means the leaf switches of one rail serve only that rail's port in every server; the spine and core tiers are shared between rails.
  • Spine and core counts are rounded up from the link totals; real designs may add switches to keep the pods symmetrical.
  • The all-reduce uses the whole of an accelerator's network bandwidth, at an efficiency you set (90% by default), and every step of a ring has the latency of the longest path. Real libraries pick algorithms and overlap steps.
  • Power per module and per switch, latencies and the in-server bandwidth are editorial defaults. The switch default (750 W) is the typical figure NVIDIA gives for a 64-port 400 Gb/s InfiniBand switch with passive cables; optics are counted apart.

Uncertainty: Switch and link counts are exact for a non-blocking fat tree and match the published reference architecture tables. Power and collective times depend on the module, latency and efficiency figures entered and are good to tens of percent.

Known limits

  • Links inside the server (NVLink and similar) and the scale-up network are not sized here; they appear only as the in-server bandwidth of the hierarchical all-reduce.
  • Congestion, adaptive routing and imperfect load balancing lower the bandwidth below the ideal that a non-blocking fat tree gives.
  • Twin-port switch cages (two links in one module) halve the module count at the switch; the transceiver count here assumes one module per link end.
  • The model does not size storage, management or out-of-band networks, or the cost of the parts.
  • The latency term for a large ring is the main reason hierarchical or tree methods win; the numbers depend on the latency figures entered, so measure your fabric.
  • The reduction arithmetic itself (the gamma term in the full cost model) is left out; it is small next to the network time for gradients on current accelerators.

Where the method comes from

Follows Al-Fares, Loukissas and Vahdat, A scalable, commodity data center network architecture (SIGCOMM 2008), with the cost model of Thakur, Rabenseifner and Gropp (2005) (opens in a new tab). The platform's version departs from it as follows.

  • The leaf radix is split by an oversubscription ratio and the topology can be rail-optimised, with a breakout of faster switch ports Why: AI clusters use oversubscribed leaves, one rail per accelerator port and split switch ports, none of which the original three-tier pod design includes.
  • The all-reduce adds a hierarchical algorithm using the bandwidth inside the server Why: Accelerator servers have a much faster internal network than the cluster network, and the flat ring of the MPICH paper ignores it.

Reference example, checked by test: Worked example in this method note and published in the NVIDIA DGX SuperPOD reference architecture for DGX H100: four scalable units (128 servers, 1,024 GPUs) at 400 Gb/s on 64-port switches, rail-optimised in two tiers, use 32 leaf and 16 spine switches and 1,024 cables between leaf and spine. The ring all-reduce time is hand-worked in the tool's unit test. Leaf switches 32; Spine switches 16; Core switches 0; Pluggable transceivers 2,048; Cables 2,048; Network power 69.1776; Bisection bandwidth 204.8; Ring all-reduce time 54.4264; Hierarchical all-reduce time 10.6737.

Versions

  • v1 (2026-10-25): First version, built from the tool idea.

All models in the register

Terms on this page

AI
Artificial intelligence (AI): software that learns patterns from data to classify, predict or generate, rather than following only hand-written rules.
Accelerator
Any specialised processor attached to a host system to run a class of work faster or more efficiently than a CPU can.
Collective communication
Coordinated data exchange patterns across a group of processes, such as all-reduce, all-gather, reduce-scatter and all-to-all.
Transceiver
An integrated device combining the transmit and receive signal chains for a communication link, typically including LNA, mixers, filters, VGAs, synthesiser and data converters.
Bandwidth
In meeting jargon, a person's or team's available working capacity rather than any data rate.
InfiniBand
A switched fabric with native RDMA, credit-based flow control and very low latency, long the default back-end network for HPC clusters and large AI training deployments.
NVLink
NVIDIA's proprietary high-bandwidth coherent interconnect for linking GPUs to each other and to CPUs, offering far more bandwidth per link than contemporaneous PCIe and used with NVSwitch to build...
Scale-up
Enlarging a single coherent compute domain by connecting more accelerators over a short, very high bandwidth link so they behave as one large device.
Congestion
The condition where demand for routing tracks in a region exceeds supply, measured as overflow per global routing cell.

The full glossary